Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 47
Filter
1.
Einstein (Säo Paulo) ; 20: eAO7001, 2022. tab, graf
Article in English | LILACS-Express | LILACS | ID: biblio-1375340

ABSTRACT

ABSTRACT Objective: Low platelet reactivity levels are associated with higher risk of bleeding in patients receiving dual antiplatelet therapy relative to patients with optimal platelet blockade. This study set out to evaluate the prevalence of low platelet reactivity in patients with acute myocardial infarction treated with ticagrelor and aspirin. Methods: Patients admitted with acute myocardial infarction who were already undergoing dual antiplatelet therapy with aspirin and ticagrelor were enrolled. Blood samples were collected 1 hour before and 2 hours after the maintenance dose of ticagrelor to investigate trough and the peak effects of the drug respectively. Platelet reactivity was measured by three methods: Multiplate®, PFA-100® with Innovance® PFA-P2Y cartridge and PFA-100® with Collagen/ADP cartridge. Platelet reactivity was assessed in the presence of peak levels of ticagrelor and defined according to previously validated cut-offs for each method (<19 AUC, >299 seconds and >116 seconds respectively). The level of significance was set at p<0.05. Results: Fifty patients were enrolled (44% with ST-elevation). Median duration of DAPT was 3 days (interquartile range, 2-5 days). On average, peak and trough platelet reactivity were markedly low and did not differ between different methods. Low platelet reactivity was common, but varied according to analytic method (PFA-100®/Innovance®PFA-P2Y: 86%; Multiplate®: 74%; PFA-100®/Collagen/ADP: 48%; p<0.001). Conclusion: Low platelet reactivity was very common in patients with acute myocardial infarction submitted to dual antiplatelet therapy with ticagrelor and aspirin. Findings of this study justify the investigation of less intensive platelet inhibition strategies aimed at reducing the risk of bleeding in this population, such as lower dose regimens or monotherapy with P2Y12 inhibitors.

2.
Rev. Soc. Cardiol. Estado de Säo Paulo ; 26(2): 128-133, abr.-jun.2016. tab
Article in Portuguese | LILACS | ID: lil-796517

ABSTRACT

Aproximadamente 30% dos pacientes que se apresentam com quadro de síndrome coronariana aguda têm revascularização prévia do miocárdio. Os eventos coronarianos subsequentes à revascularização do miocárdio podem ocorrer por progressão da doença aterosclerótica no leito coronário nativo, evento relacionado ao stent (reestenose, trombose ou neoaterosclerose) ou evento relacionado à cirurgia de revascularização domiocárdio (degeneração ou oclusão de enxertos cirúrgicos). Esses pacientes que necessitamde um novo procedimento de revascularização têm perfil de alto risco, geralmente associado a doença renal crônica, diabetes mellitus, doença arterial periférica, além deelevada carga aterosclerótica no leito coronariano nativo, degeneração de enxertos de veia safena e reestenose de stents. Este cenário faz com que o segundo procedimento de revascularização tenha maior risco e maior complexidade. Neste artigo discutiremos as características clínicas e as possibilidades terapêuticas de pacientes com SCA e revascularização percutânea ou cirúrgica prévias.


Around 30% of patients who present acute coronary syndrome have undergone previous myocardial revascularization. Coronary events following myocardial revascularization can occur due to progression of atherosclerotic disease in the native coronary bed, an event related to the stent (restenosis, thrombosis or neoatherosclerosis) or to the myocardial revascularization surgery (degeneration or occlusion of surgical grafts). These patients who need a new revascularization procedure have a high-risk profile, generally associated with chronic kidney disease, diabetes mellitus, and peripheral arterial disease, as well as a high atherosclerotic burden in the native coronary bed, degeneration of grafts of the saphenous vein, and restenosis of stents. This scenario confers a higher risk and greater complexity on the second revascularization procedure. In this article, we discuss the clinical characteristics and therapeutic possibilities of patients with ACS and previous percutaneous or surgical revascularization.


Subject(s)
Humans , Percutaneous Coronary Intervention/methods , Coronary Restenosis/diagnosis , Coronary Restenosis/therapy , Myocardial Revascularization/adverse effects , Acute Coronary Syndrome/diagnosis , Acute Coronary Syndrome/therapy , Angioplasty/methods , Acute Disease , Risk Factors , Stents , Thrombosis/diagnosis , Thrombosis/therapy , Coronary Vessels/surgery , Saphenous Vein , Heart Ventricles
3.
Rev. Assoc. Med. Bras. (1992) ; 62(1): 32-37, Jan.-Feb. 2016. tab, graf
Article in English | LILACS | ID: lil-777440

ABSTRACT

SUMMARY Introduction: the EuroSCORE II and STS are the most used scores for surgical risk stratification and indication of transcatheter aortic valve implantation (TAVI). However, its role as a tool for mortality prediction in patients undergoing TAVI is still unclear. Objective: to evaluate the performance of the EuroSCORE II and STS as predictors of in-hospital and 30-day mortality in patients undergoing TAVI. Methods: we included 59 symptomatic patients with severe aortic stenosis that underwent TAVI between 2010 and 2014. The variables were analyzed using Student's t-test and Fisher's exact test and the discriminative power was evaluated using receiver operating characteristic curve (ROC) and area under the curve (AUC) with a 95% confidence interval. Results: mean age was 81±7.3 years, 42.3% men. The mean EuroSCORE II was 7.6±7.3 % and STS was 20.7±10.3%. Transfemoral procedure was performed in 88.13%, transapical in 3.38% and transaortic in 8.47%. In-hospital mortality was 10.1% and 30-day mortality was 13.5%. Patients who died had EuroSCORE II and STS higher than the survivors (33.7±16.7vs. 18.6±7.3% p=0,0001 for STS and 13.9±16.1 vs. 4.8±3.8% p=0.0007 for EuroSCORE II). The STS showed an AUC of 0.81 and the EuroSCORE II of 0.77 and there were no differences in the discrimination ability using ROC curves (p=0.72). Conclusion: in this cohort, the STS and EuroSCORE II were predictors of in-hospital and 30-days mortality in patients with severe aortic stenosis undergoing TAVI.


RESUMO Introdução: STS e EuroSCORE II são os escores mais utilizados para a estratificação de risco cirúrgico e indicação do implante de válvula aórtica transcateter (TAVI). Entretanto, seu papel como ferramenta para predição de mortalidade em pacientes submetidos ao TAVI ainda é incerto. Objetivo: avaliar o desempenho do EuroSCORE II e STS como preditores de mortalidade intra-hospitalar em 30 dias em pacientes submetidos ao TAVI. Métodos: 59 pacientes com estenose aórtica importante submetidos ao TAVI entre 2010 e 2014. Variáveis foram analisadas por meio do teste t-Student e teste exato de Fisher, e o poder discriminativo foi avaliado pela curva ROC e área sob a curva, acompanhada de intervalo de confiança de 95%. Resultados: a idade média foi de 81±7,3 anos, 42,3% homens. Média do EuroSCORE II foi de 6,07±7,3%, e do STS, 20,7±10,3%. Procedimento transfemoral foi realizado em 88,13%, transapical, em 3,38% e transaórtico, em 8,47%. A mortalidade intra-hospitalar foi 10,1%, e em 30 dias, 13,5%. Os pacientes que evoluíram para óbito apresentavam STS e EuroSCORE II mais elevados que os sobreviventes (33,7±16,7% vs. 18,6±7,3%; p=0,0001 para STS e 13,9±16,1% vs. 4,8±3,8%; p=0,0007 para EuroSCORE II). O STS apresentou AUC de 0,81, e o EuroSCORE II, 0,77. Não houve diferença na capacidade de discriminação pelas curvas ROC (p=0,72). Conclusão: STS e EuroSCORE II foram preditores de mortalidade intra-hospitalar em 30 dias.


Subject(s)
Humans , Male , Female , Aged , Aged, 80 and over , Risk Assessment/methods , Transcatheter Aortic Valve Replacement/mortality , Aortic Valve Stenosis/surgery , Aortic Valve Stenosis/mortality , Brazil , Reproducibility of Results , Retrospective Studies , Risk Factors , Sensitivity and Specificity , Hospital Mortality , Transcatheter Aortic Valve Replacement/adverse effects
4.
In. Kalil Filho, Roberto; Fuster, Valetim; Albuquerque, Cícero Piva de. Medicina cardiovascular reduzindo o impacto das doenças / Cardiovascular medicine reducing the impact of diseases. São Paulo, Atheneu, 2016. p.361-373.
Monography in Portuguese | LILACS | ID: biblio-971545
5.
In. Kalil Filho, Roberto; Fuster, Valetim; Albuquerque, Cícero Piva de. Medicina cardiovascular reduzindo o impacto das doenças / Cardiovascular medicine reducing the impact of diseases. São Paulo, Atheneu, 2016. p.631-654.
Monography in Portuguese | LILACS | ID: biblio-971558
7.
Rev. bras. cardiol. invasiva ; 23(4): 247-250, out.-dez. 2015. tab
Article in Portuguese | LILACS | ID: biblio-846599

ABSTRACT

Introdução:Recentemente, o estudo MOZART demonstrou que a utilização do ultrassom intracoronário (USIC) para guiar a intervenção coronariana percutânea (ICP) diminui o volume de contraste utilizado no procedimento. Avaliamos a incidência de eventos adversos cardiovasculares tardios desses pacientes. Métodos: Pacientes com risco para nefropatia induzida por contraste (NIC) ou para sobrecarga de volume, e com indicação de ICP, foram randomizados para procedimento guiado pela angiografia ou USIC, e acompanhados por um período de 1 ano. Resultados: Incluídos 83 pacientes nos grupos ICP guiado por angiografia (n = 42) ou USIC (n = 41), sendo que 77,1% eram diabéticos e 44,6% tinham clearance de creatinina < 60mL/min/1,73m2. As características clínicas e angiográficas não mostraram diferenças entre os grupos. A maioria tinha lesões tipo B2/C (89,8%) e uma mediana de dois stents foram usados (intervalo interquartil: 1,0­2,0 stents). O tempo de procedimento da ICP guiada por USIC foi 14 minutos maior do que no grupo guiado por angiografia (p = 0,006). No entanto, os grupos não diferiram em relação ao tempo de fluoroscopia ou à média de aquisições de imagem por procedimento. A NIC ocorreu em 19,0% vs. 7,3% (p = 0,26). No período de seguimento de 1 ano, 12% dos pacientes apresentaram algum evento cardiovascular maior, sendo dois óbitos (um para cada grupo), e não houve diferenças entre os grupos. Conclusões: A estratégia de redução de contraste com a ICP guiada pelo ultrassom intravascular, em pacientes com risco para NIC ou sobrecarga de volume, mostrou­se segura a curto e longo prazos.


Background: Recently, the MOZART study demonstrated that using intravascular ultrasound (IVUS) for guiding percutaneous coronary intervention (PCI) reduces the volume of contrast used in the procedure. The authors assessed the incidence of late adverse cardiovascular events in these patients. Methods: Patients at risk for contrast­induced nephropathy (CIN) or volume overload were randomized to angiography­guided versus IVUS­guided PCI, and followed­up for a 1­year period. Results: Eighty­three patients were included in the angiography­guided (n = 42) or IVUS­guided (n = 41) groups, of whom 77.1% were diabetics and 44.6% had creatinine clearance < 60mL/min/1.73m2. Clinical and angiographic characteristics did not differ between the groups. Most had type B2/C lesions (89.8%) and a median of two stents were used (interquartile range: 1.0­2.0 stents). The duration of IVUS­guided PCI was 14minutes longer than the angiography­guided PCI group (p = 0.006). However, the groups did not differ regarding fluoroscopy time or mean image acquisitions per procedure. CIN occurred in 19.0% vs. 7.3% (p = 0.26). During the 1­year follow­up, 12% of patients had a major cardiovascular event, with two deaths (one in each group), and no differences were found between groups. Conclusions: The contrast reduction strategy with IVUS­guided PCI in patients at risk for CIN or volume overload was shown to be safe in the short and long term


Subject(s)
Humans , Male , Female , Ultrasonography/methods , Treatment Outcome , Contrast Media/administration & dosage , Percutaneous Coronary Intervention/methods , Diagnostic Imaging/methods , Angiography/methods , Cardiovascular Diseases/physiopathology , Stents , Prospective Studies , Creatinine
8.
Rev. bras. cardiol. invasiva ; 23(4): 279-281, out.-dez. 2015. ilus
Article in Portuguese | LILACS | ID: biblio-846619

ABSTRACT

A dissecção coronária espontânea é uma entidade rara e, por conseguinte, de etiologia, fisiopatologia e tratamento ainda não estabelecidos. Acomete, em geral, mulheres jovens, sem os clássicos fatores de risco cardiovascular, comumente ao longo do ciclo gravídico-puerperal. Vários fatores influenciam na estratégia de tratamento, como quadro clínico, status hemodinâmico, topografia da dissecção, número de artérias afetadas e fluxo coronário distal. Como no caso relatado, em pacientes estáveis, com dissecções bem delimitadas e, sobremodo, quando o fluxo coronário é reestabelecido, pode-se optar por uma abordagem conservadora, em razão da alta incidência de resolução espontânea e da baixa incidência de eventos adversos a longo prazo


Spontaneous coronary dissection is a rare entity and, therefore, its etiology, pathophysiology, and treatment are not yet established. It affects mainly young women without the classic cardiovascular risk factors, commonly during the pregnancy-childbirth cycle. Several factors influence the treatment strategy, such as clinical presentation, hemodynamic status, topography, number of affected arteries, and distal coronary flow. As in the reported case, in stable patients with well-defined dissections and mainly when the coronary flow has been re-established, one can choose a conservative approach, due to the high incidence of spontaneous resolution and low incidence of long-term adverse events


Subject(s)
Humans , Female , Middle Aged , Therapeutics , Coronary Disease/therapy , Dissection/methods , Prognosis , Angiography/methods , Clinical Diagnosis/diagnosis , Coronary Vessels/surgery
9.
Rev. bras. cardiol. invasiva ; 23(2): 130-133, abr.-jun. 2015. tab, graf
Article in Portuguese | LILACS | ID: lil-786996

ABSTRACT

Introdução: A medida acurada do tamanho do anel valvar aórtico tem importância fundamental para o planejamento do implante percutâneo de prótese valvar aórtica transcateter (TAVI) em pacientes comestenose valvar aórtica grave. Embora haja recomendação de se realizar a medida na sístole, pouco se sabe sobre a importância das diferenças entre as dimensões sistólica e diastólica do anel. Métodos: Pacientes consecutivos referidos para TAVI foram avaliados com tomografia computadorizada para medida do anel valvar na sístole e na diástole. Área, circunferência, diâmetros máximo e mínimo, e seus diâmetros médios derivados foram obtidos em ambas as fases do ciclo cardíaco. Gráficos de Bland Altman foram construídos para se avaliarem as diferenças entre as medidas.Resultados: Foram incluídos na análise 41 pacientes com estenose aórtica grave. As médias da área, circunferência e diâmetros médios foram discretamente maiores na sístole. No entanto, em 35% dos pacientes, as dimensões diastólicas foram maiores. Essas diferenças, embora estatisticamente significantes, foram pequenas (a maior diferença de 0,6 mm no diâmetro médio). Gráficos de Bland Altman revelaram bons níveis de concordância entre as medidas sistólicas e diastólicas em todos os parâmetros avaliados.Conclusões: Observamos pequenas diferenças nas dimensões sistólicas e diastólicas no anel valvar aórtico à tomografia computadorizada, as quais, embora estatisticamente significantes, provavelmente não impactam na seleção da prótese e nem no resultado do procedimento.


Background: Accurate aortic valve annulus sizing has critical importance for the planning of percutaneous transcatheter aortic valve implantation (TAVI) in patients with severe aortic valve stenosis. Although there is a recommendation to perform the measurement during systole, little is known about the importance of the differences between systolic and diastolic dimensions of the annulus. Methods: Consecutive patients referred for TAVI were evaluated with computed tomography for valve annulus sizing during systole and diastole. Area, circumference, minimum and maximum diameters, and their mean derived diameters were obtained in both phases of the cardiac cycle. Bland-Altman plots were constructed to evaluate the differences between the measures. Results: The analysis included 41 patients with severe aortic stenosis. Mean area, circumference, and diameters were slightly greater in systole. However, in 35% of patients, diastolic dimensions were greater.These differences, although statistically significant, were small (the greatest difference of 0.6 mm in mean diameter). Bland-Altman plots showed good agreement between systolic and diastolic measurements on all parameters evaluated Conclusions: Small differences were observed in the systolic and diastolic dimensions of the aortic valve annulus with computed tomography scan, which, although statistically significant, probably do not impact the selection of prosthesis or the procedure outcome.


Subject(s)
Humans , Male , Female , Aged, 80 and over , Diastole/physiology , Transcatheter Aortic Valve Replacement/methods , Systole/physiology , Tomography, X-Ray Computed/methods , Data Interpretation, Statistical , Femoral Artery/surgery , Echocardiography/methods , Aortic Valve Stenosis/therapy , Prostheses and Implants
10.
Rev. bras. cardiol. invasiva ; 23(1): 58-60, abr.-jun.2015. tab
Article in Portuguese | LILACS | ID: lil-782177

ABSTRACT

O objetivo deste estudo foi avaliar o grau de acurácia, precisão, correlação e concordância entre as medidas realizadas por um software de angiografia coronária quantitativa (QCA) online de calibração automática. Métodos: Estudo piloto que analisou imagens angiográficas de dez pacientes com um software de QCA online nas calibrações automáticas Auto ISO (calibração automática do isocentro) e Auto TOD (Table-to Object Distance). Foi realizada a medida do calibre do cateter pelos dois métodos, e o diâmetro de referência foi computado. Essas medidas foram comparadas com a medida do diâmetro do cateter quanto à acurácia, precisão e concordância. Resultados: O diâmetro médio real dos cateteres era de 1,75 ± 0,32 mm (variando entre 1,33 e 2,67 mm). A aferição dos cateteres pela QCA TOD e pela QCA ISO resultou em diâmetros médios de 1,78 ± 0,37 mm e 1,88 ± 0,38 mm, respectivamente. A acurácia/precisão da QCA TOD e da QCA ISO foi 0,03 m/0,21 mm e 0,12 mm/0,20 mm, respectivamente. As medidas da QCA TOD e da QCA ISO estiveram entre os limites de concordância em 96,3 e 94,7% dos casos, respectivamente. As medidas da QCA TOD e da QCA ISO correlacionaram-se significativamente (rs = 0,93; p < 0,01). No entanto, apesar da pequena diferença entre os métodos (0,10 ± 0,10 mm), as medidas da QCA ISO foram estatisticamente maiores que aquelas obtidas com a QCA TOD (p < 0,01). Conclusões: A QCA online com calibração automática apresentou boa acurácia, precisão e correlação,podendo representar uma ferramenta promissora no laboratório de hemodinâmica...


The objective of this study was to evaluate the degree of accuracy, precision, correlation, andagreement between the measurements performed by online Quantitative Coronary Angiography (QCA)software with automatic calibration.Methods: Pilot study that analyzed angiographic images of ten patients through online QCA softwareusing Auto ISO (automatic calibration isocenter) and Auto TOD (Table-to-Object Distance) automatic calibration. Catheter size was measured by both methods and the reference diameter was computed. These measurements were compared with the measurement of catheter diameter regarding accuracy, precision,and agreement. Results: The actual average of the catheter diameter was 1.75 ± 0.32 mm (range 1.33 to 2.67 mm). The measurement of catheters by TOD QCA and ISO QCA resulted in mean diameters of 1.78 ± 0.37 mm and 1.88± 0.38 mm, respectively. The accuracy/precision of the TOD QCA and the ISO QCA was 0.03 mm/0.21 mmand 0.12 mm/0.20 mm, respectively. The TOD QCA and ISO QCA measures were among the limits ofagreement in 96.3 and 94.7% of cases, respectively, and were significantly correlated (rs = 0.93, p < 0.01). However, despite the small difference between the methods (0.10 ± 0.10 mm), the ISO QCA measures were significantly higher than those obtained by the TOD QCA (p < 0.01). Conclusions: Online QCA with automatic calibration has good accuracy, precision, and correlation, which may represent a promising tool in the catheterization laboratory...


Subject(s)
Humans , Male , Female , Coronary Angiography/methods , Coronary Disease/diagnosis , Coronary Disease/therapy , Dimensional Measurement Accuracy , Data Interpretation, Statistical , Catheters , Pilot Projects , Stents
11.
Rev. bras. cardiol. invasiva ; 23(1): 38-41, abr.-jun.2015. tab, graf
Article in Portuguese | LILACS | ID: lil-782173

ABSTRACT

A aterectomia rotacional com incorporação de novas estratégias ablativas tem sido proposta para o preparo de lesões extremamente calcificadas. Entretanto, pouco se conhece a respeito da adoçãodessas novas estratégias na prática contemporânea e sobre a evolução tardia dos pacientes submetidos aesse tratamento. Objetivamos avaliar os aspectos técnicos da aterectomia e a evolução tardia dos pacientesquanto à ocorrência de eventos cardiovasculares adversos maiores (ECAM). Métodos: Estudo retrospectivo e unicêntrico, incluindo todos os pacientes submetidos à aterectomiarotacional como parte do tratamento de lesões coronárias com calcificação extrema ou falha de dilataçãoem procedimento prévio, no período de julho de 2012 a novembro de 2014. Foram definidos como ECAM: óbito, infarto agudo do miocárdio com onda Q ou nova revascularização do vaso-alvo.Resultados: Foram submetidos à aterectomia 29 pacientes com idade média de 69,5 ± 7,6 anos. A médiada relação oliva/vaso foi de 0,54 ± 0,07; a velocidade de rotação inicial adotada foi de 161.000 ± 13.928 e a taxa de utilização de cutting balloon pós-aterectomia foi de 45,1%. Sucesso angiográfico foi obtido em todos os procedimentos. Na evolução tardia, a mediana de tempo de seguimento foi de 13,2 meses (intervalo interquartil: 4,0 a 17,4 meses). Foram registrados um óbito por causa não cardíaca e duas novas revascularizações do vaso-alvo. A média do tempo de sobrevivência livre de ECAM foi de 29,7 ± 2,1 meses.Conclusões: A aterectomia rotacional contemporânea incorporou estratégias menos agressivas de ablação,com elevada taxa de sucesso imediato e baixa ocorrência de ECAM na evolução tardia...


Rotational atherectomy with new ablative strategies have been proposed for the treatment of extremely calcified lesions prior to stent implantation. Nevertheless, few data are available about the adoption of these new strategies in contemporary practice and about late outcomes of patients undergoing this therapy. Methods: From July 2012 to November 2014, a retrospective single center registry was conducted, including all patients undergoing rotational atherectomy as part of the treatment of coronary arteries with heavy calcification or previous failed dilation. We evaluated technical aspects of atherectomy and late outcomes of patients for the occurrence of major adverse cardiovascular events (MACE), defined as death, Q-wave myocardial infarction or repeat target vessel revascularization.Results: Twenty-nine patients with a mean age of 69.5 ± 7.6 years, underwent atherectomy. The averageburr-to-artery ratio was 0.54 ± 0.07, the initial rotational speed was 161.000 ± 13.928 and the rate of cuttingballoon utilization after atherectomy was 45.1%. Angiographic success was achieved in all procedures. The median follow-up time was 13.2 months (IQ: 4.0-17.4) and there were three events: 1 death of non cardiac cause and 2 new target vessel revascularizations. The mean MACE-free survival time was 29.7 ± 2.1 months. Conclusions: Contemporary rotational atherectomy incorporates less aggressive strategies of ablation with high rates of acute success and low occurrence of major adverse cardiovascular events during late follow-up...


Subject(s)
Humans , Male , Female , Aged , Atherectomy, Coronary/methods , Coronary Artery Disease/complications , Coronary Artery Disease/diagnosis , Percutaneous Coronary Intervention/methods , Drug Therapy , Angioplasty, Balloon/methods , Aspirin/administration & dosage , Vascular Calcification/therapy , Retrospective Studies , Risk Factors , Heparin/administration & dosage
12.
Arq. bras. cardiol ; 103(5): 410-417, 11/2014. tab, graf
Article in English | LILACS | ID: lil-730366

ABSTRACT

Background: The hemodynamic effects of noninvasive ventilation with positive pressure in patients with pulmonary hypertension without left ventricular dysfunction are not clearly established. Objectives: Analyze the impact of increasing airway pressure with continuous positive airway pressure on hemodynamic parameters and, in particular, on cardiac output in patients with variable degrees of pulmonary hypertension. Methods: The study included 38 patients with pulmonary hypertension caused by mitral stenosis without left ventricular dysfunction or other significant valvulopathy. The hemodynamic state of these patients was analyzed in three conditions: baseline, after continuous positive pressure of 7 cmH2O and, finally, after pressure of 14 cmH2O. Results: The population was composed of predominantly young and female individuals with significant elevation in pulmonary arterial pressure (mean systolic pressure of 57 mmHg). Of all variables analyzed, only the right atrial pressure changed across the analyzed moments (from the baseline condition to the pressure of 14 cmH2O there was a change from 8 ± 4 mmHg to 11 ± 3 mmHg, respectively, p = 0.031). Even though there was no variation in mean cardiac output, increased values in pulmonary artery pressure were associated with increased cardiac output. There was no harmful effect or other clinical instability associated with use application of airway pressure. Conclusion: In patients with venocapillary pulmonary hypertension without left ventricular dysfunction, cardiac output response was directly associated with the degree of pulmonary hypertension. The application of noninvasive ventilation did not cause complications directly related to the ventilation systems. .


Fundamento: Os efeitos hemodinâmicos da ventilação não invasiva com pressão positiva em pacientes com hipertensão pulmonar sem disfunção ventricular esquerda não estão bem estabelecidos. Objetivos: Analisar o impacto da pressurização aérea crescente através da pressão positiva contínua das vias aéreas nos parâmetros hemodinâmicos e, principalmente, no débito cardíaco de pacientes com graus variáveis de hipertensão pulmonar. Métodos: Foram incluídos 38 pacientes com hipertensão pulmonar causada por estenose mitral sem disfunção ventricular esquerda ou outra valvopatia significativa. O estado hemodinâmico deses pacientes foi estudado em três condições: basal, após uso de pressão positiva contínua de 7 cmH2O e , finalmente, após pressão de 14 cmH2O. Resultados: A população foi composta por indivíduos predominantemente jovens, do sexo feminino e com elevação significativa da pressão arterial pulmonar (pressão sistólica média de 57 mmHg). De todas as variáveis analisadas, apenas a pressão de átrio direito apresentou variação ao longo dos momentos estudados (da condição basal para a de pressão de 14 cmH2O houve aumento de 8 ± 4 mmHg para 11 ± 3 mmHg, respectivamente, p = 0,031). Apesar de não ter havido variação do valor médio do débito cardíaco, valores mais elevados de pressões na artéria pulmonar estiveram associados ao aumento do débito cardíaco. Não houve efeito deletério ou qualquer instabilidade clínica associada ao uso da pressurização das vias aéreas. Conclusão: Em pacientes com hipertensão venocapilar pulmonar sem disfunção ventricular esquerda, a resposta ...

13.
Rev. bras. cardiol. invasiva ; 22(3): 286-292, Jul-Sep/2014. graf
Article in Portuguese | LILACS | ID: lil-732789

ABSTRACT

Introdução: A despeito de suas reconhecidas limitações, a angiografia coronária invasiva é o método mais usado (muitas vezes único) para a adoção de estratégias terapêuticas em pacientes submetidos a cateterismo cardíaco diagnóstico. A mensuração de reserva de fluxo fracionada (FFR) tem sido empregada em diversos estudos, fundamentalmente no contexto de pacientes em que a avaliação angiográfica per se indica a necessidade de intervenção sobre as lesões coronárias. No entanto, o método praticamente não foi ainda testado em condições opostas, no cenário clínico em que as obstruções, angiograficamente, não indicariam intervenções. O propósito deste trabalho, a ser realizado de forma piloto em dois centros, é testar a hipótese de que também para lesões intermediárias, nas quais a angiografia não demonstra necessidade de intervenção coronária, a medida de FFR resultaria em alteração da conduta terapêutica baseada em angiografia. Métodos: Serão incluídos pacientes consecutivos e clinicamente estáveis, com doença coronária em segmento proximal e/ou médio de um ou mais vasos epicárdicos (diâmetro > 2,5 mm), apresentando obstruções entre 40 e 70%, por estimativa visual. Em seguida, a conduta terapêutica (clínica ou intervencionista) baseada em angiografia, relativamente a essas lesões, será ...


Background: Despite its well-known limitations, invasive coronary angiography remains the most used, and often times the only method used to define treatment strategies in patients undergoing diagnostic cardiac catheterization. Measurement of coronary fractional flow reserve (FFR) has been used in several studies in patients for whom an interventional the rapy strategy was determined based on angiography. However, this method has not been tested in the opposite scenario, in which the angiographic evaluation does not indicate the need for interventions. The purpose of this pilot study, to be performed in two sites, is to test the hypothesis that for intermediate injuries, in which angiography does not indicate the need for coronary intervention, measurement of FFR might change the therapeutic approach based on angiography. Methods: Consecutive clinically stable patients, with coronary disease in the proximal or middle segment of one or more epicardial vessels (diameter > 2.5 mm), with injuries between 40 and 70% by visual estimation will be enrolled in this trial. The treatment approach (clinical or interventional) based on angiography will be defined independently and by consensus of two observers. Thereafter, patients in both groups will be randomized into two subgroups: (1) maintenance of the angiography-based therapeutic strategy; and (2) use of FFR to define therapeutic strategy. Patients with FFR < 0.80 will be treated by percutaneous or surgical revascularization, whereas patients with FFR ≥ 0.80 ...

14.
Arq. bras. cardiol ; 102(5): 432-440, 10/06/2014. tab, graf
Article in Portuguese | LILACS | ID: lil-711094

ABSTRACT

Fundamento: Stents recobertos com polímeros bioabsorvíveis e fármacos apenas na face abluminal podem ser mais seguros que stents farmacológicos com polímeros permanentes. Objetivo: Relatar os resultados experimentais com o stent Inspiron(r), um stent recoberto com polímero bioabsorvível e com liberação de sirolimus apenas da face abluminal, recentemente aprovado para uso clínico. Métodos: Foram implantados 45 stents nas artérias coronárias de 15 porcos e, no 28° dia pós-implante, foram obtidos os resultados angiográficos, de ultrassonografia intracoronária e de histomorfologia. Cinco grupos foram avaliados: Grupo I (nove stents sem recobrimento); Grupo II (nove stents com polímero bioabsorvível nas faces luminal e abluminal); Grupo III (oito stents com polímero bioabsorvível na face abluminal); Grupo IV (nove stents com polímero bioabsorvível e sirolimus nas faces luminal e abluminal); e Grupo V (dez stents com polímero bioabsorvível e sirolimus na face abluminal exclusivamente). Resultados: Observamos, para os Grupos I, II, III, IV e V respectivamente: porcentual de estenose de 29 ± 20; 36 ± 14; 33 ± 19; 22 ± 13 e 26 ± 15 (p = 0,443); perda luminal tardia (em mm) de 1,02 ± 0,60; 1,24 ± 0,48; 1,11 ± 0,54; 0,72 ± 0,44 e 0,78 ± 0,39 (p = 0,253); área neointimal (em mm2) de 2,60 ± 1,99; 2,74 ± 1,51; 2,74 ± 1,30; 1,30 ± 1,14 e 0,97 ± 0,84 (p = 0,001; Grupos IV e V versus Grupos I, II e III) e porcentual de área neointimal de 35 ± 25; 38 ± 18; 39 ± 19; 19 ± 18 e 15 ± 12 (p = 0,001; Grupo IV e V versus Grupo I, II e III). Os escores de injúria e inflamação foram baixos e sem diferenças entre os grupos. Conclusão: O stent Inspiron(r) foi seguro e inibiu significativamente a hiperplasia ...


Background: Bioabsorbable polymer stents with drug elution only on the abluminal surface may be safer than durable polymer drug-eluting stents. Objective: To report the experimental findings with the Inspiron(tm) stent - a bioabsorbable polymer-coated stent with sirolimus release from the abluminal surface only, recently approved for clinical use. Methods: 45 stents were implanted in the coronary arteries of 15 pigs. On day 28 after implantation, angiographic, intracoronary ultrasonographic and histomorphological data were collected. Five groups were analyzed: Group I (nine bare-metal stents); Group II (nine coated with bioabsorbable polymer on the luminal and abluminal surfaces); Group III (eight stents coated with bioabsorbable polymer on the abluminal surface); Group IV (nine stents with bioabsorbable polymer and sirolimus on the luminal and abluminal surfaces); and Group V (ten stents with bioabsorbable polymer and sirolimus only on the abluminal surface). Results: The following results were observed for Groups I, II, III, IV and V, respectively: percentage stenosis of 29 ± 20; 36 ± 14; 33 ± 19; 22 ± 13 and 26 ± 15 (p = 0.443); late lumen loss (in mm) of 1.02 ± 0.60; 1.24 ± 0.48; 1.11 ± 0.54; 0.72 ± 0.44 and 0.78 ± 0.39 (p = 0.253); neointimal area (in mm2 )) of 2.60 ± 1.99; 2.74 ± 1.51; 2.74 ± 1.30; 1.30 ± 1.14 and 0.97 ± 0.84 (p = 0.001; Groups IV and V versus Groups I, II and III); and percentage neointimal area of 35 ± 25; 38 ± 18; 39 ± 19; 19 ± 18 and 15 ± 12 (p = 0.001; Groups IV and V versus Groups I, II and III). Injury and inflammation scores were low and with no differences between the groups. Conclusion: The Inspiron(tm) stent proved to be safe and was able to significantly inhibit the neointimal hyperplasia observed on day 28 after implantation in porcine coronary arteries. .


Subject(s)
Animals , Absorbable Implants , Biopolymers , Coated Materials, Biocompatible , Coronary Vessels/drug effects , Drug-Eluting Stents , Immunosuppressive Agents/administration & dosage , Sirolimus/administration & dosage , Coronary Angiography , Coronary Vessels , Drug Delivery Systems/methods , Materials Testing , Reference Values , Reproducibility of Results , Swine , Time Factors
16.
Arq. bras. cardiol ; 102(5,supl.1): 1-41, 05/2014. tab
Article in English | LILACS | ID: lil-709328
17.
Rev. bras. cardiol. invasiva ; 22(2): 120-124, Apr-Jun/2014. tab, graf
Article in Portuguese | LILACS | ID: lil-722250

ABSTRACT

Introdução: A utilização da via radial para a realização de cateterismo cardíaco diagnóstico e intervenção coronária percutânea varia entre os diversos centros de hemodinâmica. Descrevemos as tendências do uso dessa via de acesso ao longo dos últimos 14 anos num serviço terciário. Métodos: Foram identificados procedimentos coronarianos consecutivos realizados de 1999 a 2013, em um único centro, em pacientes com idade ≥ 35 anos. Dados como idade, sexo, fonte provedora de recursos (Sistema de Saúde Público ou Saúde Suplementar/Privado) e complexidade do procedimento (diagnóstico ou terapêutico) foram retrospectivamente analisados. Resultados: Foram incluídos 103.253 procedimentos, dos quais o Sistema Único de Saúde (SUS) foi o provedor de recursos em 77% dos casos. A média de idades dos pacientes foi 62,2 ± 11,3 e 58,8% eram do sexo masculino. A via radial foi utilizada em 6.402 (6,2%) dos procedimentos, apresentando ascensão significativa ao longo do tempo, mais evidente quando analisada comparativamente nos seis períodos de experiência do serviço: 0,2%, 0,6%, 3,1%, 2,1%, 6,9% e 24,4%, respectivamente (p < 0,01). Porcentuais ainda maiores do uso da via radial foram encontrados, restringindo-se aos procedimentos realizados pelo SUS e quando apenas os cateterismos cardíacos diagnósticos foram contabilizados. Houve também mudança no perfil da via de acesso, ainda que de menor monta, no setor de Saúde Suplementar/Privado. Conclusões: Demonstramos a progressiva modificação do perfil de utilização das vias de acesso para a realização de cateterismo cardíaco diagnóstico e intervenção coronária percutânea de um centro de grande porte ao longo do tempo. Esses dados são condizentes...


Background: The use of the radial approach for diagnostic cardiac catheterization and percutaneous coronary interventions varies among different interventional cardiology centers in the world. We describe the trends in the use of this approach over the past 14 years at a tertiary hospital. Methods: Consecutive coronary procedures performed from 1999 to 2013 at a single center, in patients aged ≥ 35 years were identified. Age, gender, resource provider (Public or Private Healthcare System) and the complexity of the procedure (diagnostic or therapeutic) were retrospectively analyzed. Results: 103,253 procedures were included. The Brazilian Public Healthcare Service (SUS - Sistema Único de Saúde) was the resource provider in 77% of the cases. Mean age of patients was 62.2 ± 11.3 years and 58% were male. The radial approach was used in 6,402 (6.2%) procedures, showing a significant rise over time, which was more evident when analyzed comparatively for the six timepoints of service experience: 0.2%; 0.6%; 3.1%; 2.1%; 6.9%, and 24.4% respectively (p < 0.01). Even larger percentages of radial approach were observed when only the procedures performed by the SUS and diagnostic cardiac catheterizations were taken into account. There were also changes in the profile of vascular access, even though smaller, in the Private Healthcare System. Conclusions: We demonstrated progressive changes in the profile of the use of access routes for diagnostic cardiac catheterization and percutaneous coronary interventions at a large center over time. These data are consistent with the global trend and are significantly robust, especially when the last sextile is analyzed...


Subject(s)
Humans , Male , Female , Middle Aged , Femoral Artery/injuries , Radial Artery/physiology , Supplemental Health/standards , Unified Health System/standards , Cardiac Catheterization/methods , Vascular Access Devices/trends , Heparin/administration & dosage , Percutaneous Coronary Intervention/methods , Retrospective Studies , Data Interpretation, Statistical
18.
Rev. bras. cardiol. invasiva ; 22(2): 183-187, Apr-Jun/2014. graf
Article in Portuguese | LILACS | ID: lil-722251

ABSTRACT

A intervenção coronariana percutânea com balão farmacológico surgiu como estratégia adjunta no cenário da Cardiologia Intervencionista. Em comparação com o stent farmacológico, o balão farmacológico oferece vantagens, como a liberação imediata e homogênea do fármaco na parede arterial, a ausência de polímeros que podem induzir a reações inflamatórias crônicas e o potencial de utilizar a dupla antiagregação plaquetária por menor tempo. Além disso, em algumas situações, não são desejáveis implantes adicionais de stents, o que torna essa modalidade uma opção interessante. Relatamos aqui o caso de uma paciente em síndrome coronariana aguda, em que foi feita a opção por esse tipo de intervenção em uma reestenose de stent não farmacológico em óstio de artéria descendente anterior...


Percutaneous coronary intervention with drug-eluting balloons has emerged as an adjunctive strategy in the setting of Interventional Cardiology. When compared to drug-eluting stents, drug-eluting balloons offer advantages such as immediate and homogeneous drug release in the arterial wall, absence of polymers that can induce chronic inflammatory reactions, and the potential for using dual antiplatelet therapy for a shorter period of time. Furthermore, in some situations, additional stenting is not desirable, which turns this modality into an interesting option. We report the case of a patient with acute coronary syndrome in whom this intervention was chosen to treat an ostial left anterior descending artery in-stent restenosis...


Subject(s)
Humans , Female , Middle Aged , Angioplasty, Balloon , Coronary Restenosis/therapy , Stents/adverse effects , Coronary Vessels/physiopathology , Percutaneous Coronary Intervention , Paclitaxel/therapeutic use , Acute Coronary Syndrome/complications , Acute Coronary Syndrome/therapy
19.
Rev. bras. cardiol. invasiva ; 22(2): 149-154, Apr-Jun/2014. tab, graf
Article in Portuguese | LILACS | ID: lil-722252

ABSTRACT

Introdução: Avaliamos a segurança e eficácia do uso de protamina, guiada pelo tempo de coagulação ativado, para a remoção imediata do introdutor arterial femoral em pacientes submetidos à intervenção coronária percutânea com heparina não fracionada, com o objetivo de propor um algoritmo para a prática clínica. Métodos: Estudo prospectivo, com pacientes consecutivos, com angina estável ou com síndrome coronariana aguda de baixo ou moderado risco. Comparamos os pacientes com a retirada precoce do introdutor arterial àqueles nos quais o introdutor foi retirado de acordo com o protocolo convencional. A decisão pela remoção precoce ou convencional do introdutor foi deixada a critério do operador. Resultados: O grupo de remoção precoce (n = 149) apresentou menor tempo de manuseio do sítio de punção que o grupo de remoção convencional (58,3 ± 21,4 minutos vs. 355 ± 62,9 minutos; p < 0,01), principalmente devido à redução do tempo até a retirada do introdutor (42,3 ± 21,1 minutos vs. 338,6 ± 61,5 minutos; p < 0,01), sem impacto sobre a duração da compressão femoral (16,0 ± 3,6 minutos vs. 16,4 ± 5,1 minutos; p = 0,49). Não houve trombose hospitalar de stent e nem diferença significativa na incidência de eventos vasculares ou hemorrágicos. A incidência de outras hemorragias, que levaram à hospitalização prolongada, foi menor no grupo de remoção precoce (1,3% vs. 5,1%; p = 0,05). Conclusões: O uso seletivo de uma abordagem, para a remoção imediata do introdutor femoral guiada pelo tempo de coagulação ativado e a administração de protamina, é seguro e eficaz em pacientes submetidos à intervenção coronária...


Introduction: We evaluated the safety and efficacy of protamine administration, guided by activated clotting time, for the immediate femoral arterial sheath removal in patients undergoing percutaneous coronary intervention with unfractionated heparin in order to propose an algorithm for clinical practice. Methods: Prospective study with consecutive patients with stable angina or low-to-moderate risk acute coronary syndrome. We compared patients with an early removal of the arterial sheath to those whose sheath removal was based on a standard protocol. Results: The early removal group (n = 149) had lower access manipulation time than the conventional group (58.3 ± 21.4 minutes vs. 355.0 ± 62.9 minutes; p < 0.01), mainly due to a reduced time to sheath removal (42.3 ± 21.1 minutes vs. 338.6 ± 61.5 minutes; p < 0.01), with no impact on the duration of femoral compression (16.0 ± 3.6 minutes vs. 16.4 ± 5.1 minutes; p = 0.49). There was no stent thrombosis during hospitalization and no significant differences in the incidence of major vascular or bleeding events. The incidence of other bleeding events leading to a prolonged in-hospital length of stay was lower in the early removal group (1.3% vs. 5.1%; p = 0.05). Conclusions: The selective use of an approach for immediate femoral sheath removal, based on activated clotting time guidance and protamine administration, is a safe and effective option in patients undergoing percutaneous coronary intervention by femoral access...


Subject(s)
Humans , Male , Female , Middle Aged , Vascular Access Devices/adverse effects , Evaluation of the Efficacy-Effectiveness of Interventions , Femoral Artery , Percutaneous Coronary Intervention/methods , Anticoagulants/administration & dosage , Heparin/administration & dosage , Protamines/administration & dosage , Risk Factors , Selection Bias , Data Interpretation, Statistical , Stents
20.
Rev. bras. cardiol. invasiva ; 22(1): 32-35, Jan-Mar/2014. tab, graf
Article in Portuguese | LILACS | ID: lil-712738

ABSTRACT

Introdução: A dissecção espontânea de artéria coronária é causa rara de síndrome coronariana aguda e, em mais de 70% das vezes, o diagnóstico é feito por meio de necrópsia. O tratamento ideal ainda é incerto, sendo a intervenção coronária percutânea, a cirurgia de revascularização miocárdica e o tratamento clínico as opções terapêuticas. O objetivo deste trabalho foi avaliar as características clínicas, o tratamento e a evolução de uma série de casos de dissecção espontânea de artéria coronária. Métodos: Estudo retrospectivo, unicêntrico, baseado em análise de banco de dados de um serviço de alta complexidade em cardiologia. Resultados: Identificamos 25 pacientes com dissecção espontânea de artéria coronária, dos quais 56% eram do sexo feminino, com idade de 48,8 ± 10 anos. Apenas 24% não apresentaram fator de risco para aterosclerose e, em 92% dos casos, o quadro clínico foi de síndrome coronária aguda. A artéria descendente anterior foi o vaso mais acometido (48%) e houve apenas um caso envolvendo múltiplos vasos. A estratégia conservadora foi realizada em 56%, a intervenção coronária percutânea em 40% e a revascularização miocárdica em 4%. A taxa livre de eventos hospitalares e tardios foi de 92 e 84,2%, respectivamente. Conclusões: A dissecção espontânea de artéria coronária foi predominante em mulheres jovens, com pelo menos um fator de risco para doença arterial coronariana. A escolha de diferentes estratégias terapêuticas confirma a natureza ainda controversa da abordagem ideal da dissecção espontânea de artéria coronária. Acreditamos que o tratamento ideal ainda seja o individualizado.


Background: Spontaneous coronary artery dissection is a rare cause of acute coronary syndrome and diagnosis is made by necropsy in more than 70% of the cases. Optimal treatment is still uncertain, and the treatment options are percutaneous coronary intervention, coronary artery bypass surgery and medical therapy. The objective of this study was to evaluate the clinical characteristics, treatment modalities and outcome of a series of cases with spontaneous coronary artery dissection. Methods: Retrospective, single-center study, based on the analysis of the database at a high-complexity cardiology service. Results: We identified 25 patients with spontaneous coronary artery dissection, 56% were female, with a mean age of 48.8 ± 10 years. Only 24% had no risk factor for atherosclerosis and in 92% of the cases, the clinical presentation was of acute coronary syndrome. The left anterior descending artery was the most commonly affected vessel (48,1%) and there was only one case involving multiple vessels. The conservative approach was used in 56%, percutaneous coronary intervention in 40% and coronary artery bypass grafting in 4%. The in-hospital and late event-free survival was 92% and 84.2%, respectively. Conclusions: Spontaneous coronary artery dissection predominated in young women, with at least one risk factor for coronary artery disease. The choice of different therapeutic strategies confirms the still controversial nature of the optimal approach for spontaneous coronary artery dissection. We believe that individualized therapy is still the optimal modality.


Subject(s)
Humans , Male , Female , Middle Aged , Coronary Artery Disease/complications , Coronary Artery Disease/physiopathology , Myocardial Infarction/complications , Myocardial Infarction/physiopathology , Percutaneous Coronary Intervention/methods , Dissection , Retrospective Studies , Stents , Coronary Vessels/physiopathology
SELECTION OF CITATIONS
SEARCH DETAIL